<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Imaging | Earthline Company Limited</title>
	<atom:link href="https://www.earthline.co.th/product-category/imaging/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.earthline.co.th</link>
	<description>บริษัท เอิร์ธ ไลน์ จำกัด</description>
	<lastBuildDate>Fri, 15 Nov 2024 11:59:55 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>

<image>
	<url>https://www.earthline.co.th/wp-content/uploads/2024/11/cropped-EL-32x32.png</url>
	<title>Imaging | Earthline Company Limited</title>
	<link>https://www.earthline.co.th</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Molecular breast imaging (MBI) NM750b</title>
		<link>https://www.earthline.co.th/product/smartbeast/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Fri, 15 Nov 2024 11:36:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.earthline.co.th/?post_type=product&#038;p=38730</guid>

					<description><![CDATA[<p><img class="wp-image-38733 alignleft" src="https://www.earthline.co.th/wp-content/uploads/2024/11/Smartbeast-logo.png" alt="" width="213" height="74" /></p>
<p>Smartbeast NM750b<br />
Making advanced breast diagnostics<br />
affordable, accessible &#38; comfortable</p>
<p>&#160;</p>
<p>Molecular breast imaging (MBI) has been referred to as both MBI and breast-specific gamma imaging (BSGI), depending on the type of camera used. For consistency, the term MBI will be used to refer to these techniques, which use small field-of-view gamma cameras designed specifically for breast imaging using technetium-99m sestamibi.</p>
The post <a href="https://www.earthline.co.th/product/smartbeast/">Molecular breast imaging (MBI) NM750b</a> first appeared on <a href="https://www.earthline.co.th">Earthline Company Limited</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="1024" height="536" src="https://www.earthline.co.th/wp-content/uploads/2024/11/banner-1024x536.jpg" class="vc_single_image-img attachment-large" alt="" title="banner" srcset="https://www.earthline.co.th/wp-content/uploads/2024/11/banner-1024x536.jpg 1024w, https://www.earthline.co.th/wp-content/uploads/2024/11/banner-600x314.jpg 600w, https://www.earthline.co.th/wp-content/uploads/2024/11/banner-300x157.jpg 300w, https://www.earthline.co.th/wp-content/uploads/2024/11/banner-768x402.jpg 768w, https://www.earthline.co.th/wp-content/uploads/2024/11/banner.jpg 1200w" sizes="(max-width: 1024px) 100vw, 1024px"  data-dt-location="https://www.earthline.co.th/?attachment_id=38735" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="177" height="300" src="https://www.earthline.co.th/wp-content/uploads/2024/11/Smartbeast1-177x300.jpg" class="vc_single_image-img attachment-medium" alt="" title="Smartbeast1" srcset="https://www.earthline.co.th/wp-content/uploads/2024/11/Smartbeast1-177x300.jpg 177w, https://www.earthline.co.th/wp-content/uploads/2024/11/Smartbeast1.jpg 502w" sizes="(max-width: 177px) 100vw, 177px"  data-dt-location="https://www.earthline.co.th/?attachment_id=38736" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>In 1997, the Food and Drug Administration (FDA) approved the use of a radiopharmaceutical, technetium-99m sestamibi (Miraluma) for scintimammography, which used a conventional gamma camera to image the breast. Technetium-99m sestamibi, showed a high propensity to accumulate in breast tumors, which allowed for “functional imaging” not affected by anatomic characteristics such as breast density or surgical distortion. There are two mechanisms by which Technetium-99m sestamibi accumulates in breast tumors. The first is that it binds preferentially to the mitochondria in cells; since cancers have a high density of mitochondria (which is a marker for proliferative activity) they accumulate more technetium-99m sestamibi than the adjacent normal tissue.<sup>1</sup> Secondly, breast tumors produce significant neoangiogenesis that enables increased uptake of the radiopharmaceutical.<sup>2</sup></p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Although scintimammography with conventional gamma cameras showed good sensitivity and specificity for larger tumors, its low sensitivity for tumors smaller than 15 mm did not meet prevailing standards for breast imaging.<sup>3, 4</sup> Improvements in gamma camera technology and optimized image acquisition parameters allowed for higher sensitivity for detecting subcentimeter lesions, and ushered in the upgraded technology to now be referred to as MBI. Two types of gamma cameras are currently available: 1) multicrystal array detectors using sodium iodide, and 2) cadmium zinc telluride (CZT) direct conversion detectors.</p>
<p>The use of cadmium zinc telluride (CZT) direct conversion detectors showcase a technology upgrade in nuclear medicine where photon energy released by a radiopharmaceutical, such as technetium-99m sestamibi, is directly converted into electric signals allowing for accurate identification of event location and energy. With computer and software technology, complex calculations can be performed very quickly to convert the detected radiation into images and information that is useful for radiologists.</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="200" height="300" src="https://www.earthline.co.th/wp-content/uploads/2024/11/CZT-200x300.jpg" class="vc_single_image-img attachment-medium" alt="" title="CZT" srcset="https://www.earthline.co.th/wp-content/uploads/2024/11/CZT-200x300.jpg 200w, https://www.earthline.co.th/wp-content/uploads/2024/11/CZT-600x898.jpg 600w, https://www.earthline.co.th/wp-content/uploads/2024/11/CZT-684x1024.jpg 684w, https://www.earthline.co.th/wp-content/uploads/2024/11/CZT.jpg 696w" sizes="(max-width: 200px) 100vw, 200px"  data-dt-location="https://www.earthline.co.th/?attachment_id=38737" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h3 class="page-section-header">LOW BREAST RADIATION RISK COMPARED TO MAMMOGRAPHY</h3>
<p class="page-section-paragraph">Optimizations in detector design, patient preparation, and radiopharmaceutical delivery have reduced the administered activity from 740–1,100MBq (20–30 mCi) to the current off-label standard of 240–300MBq (6.5–8 mCi).<sup>5, 6</sup> The average absorbed radiation dose to the breast from 300MBq (8 mCi) of 99mTc-sestamibi is estimated to be 1.1mGy, compared with 3.0–4.5mGy that is associated with mammography and breast tomosynthesis (3D mammography).<sup>7</sup></p>
<p class="page-section-paragraph">Since 99mTc-sestamibi is systemically distributed, tissues outside the breast receive the largest radiation dose. The estimated effective (whole-body) dose for 300MBq (8 mCi) of 99mTc-sestamibi is 2.1–2.6 mSv, which is at, or lower than, annual natural background levels (~3 mSv).<sup>8</sup> For reference, the effective dose of chest CT can approach 6 mSv.<sup>9</sup> Tissues with the highest exposures include the colon (7.1mGy), urinary bladder (3.2mGy), and gallbladder (11.5mGy).<sup>10</sup> Various organizations assessing radiation risk and radiation protection (Health Physics Society, American Association of Physicists in Medicine, International Organization for Medical Physics, and United Nations Scientific Committee on the Effects of Atomic Radiation) state that risks from radiation doses of less than 100 mSv are not significantly different from zero.8 Thus, current MBI radiation exposure is deemed to pose negligible risk to the patient, with minimal theoretic risk of inducing cancer in any of these organs.8 The administered activity of 99mTc-sestamibi for MBI continues to decrease with technologic advancement. Tao et al. showed that new image-processing algorithms maintain lesion conspicuity with a simulated half-dose (150MBq [4 mCi]) injection.<sup>11</sup> Furthermore, continued advances in CZT module design will improve sensitivity and should allow further dose reduction.</p>

		</div>
	</div>
</div></div></div></div>
</div>The post <a href="https://www.earthline.co.th/product/smartbeast/">Molecular breast imaging (MBI) NM750b</a> first appeared on <a href="https://www.earthline.co.th">Earthline Company Limited</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dilon 6800 Molecular Breast Imagine System</title>
		<link>https://www.earthline.co.th/product/dilon-6800/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Fri, 04 Mar 2022 03:44:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.earthline.co.th/?post_type=product&#038;p=38205</guid>

					<description><![CDATA[<h3><img class=" wp-image-38212 alignright" src="https://www.earthline.co.th/wp-content/uploads/2022/03/Dilon-Logo-300x149.png" alt="" width="169" height="84" /></h3>
<h3>The Dilon Molecular Breast Imagine System</h3>
<p>Dilon Diagnostics provides a complete system for breast-specific gamma imaging (BSGI) and biopsy guidance. The Dilon 6800 gamma camera supports the diagnostic procedure of molecular breast imaging, known as BSGI or MBI, with high-resolution digital imaging optimized for early breast cancer detection.</p>
The post <a href="https://www.earthline.co.th/product/dilon-6800/">Dilon 6800 Molecular Breast Imagine System</a> first appeared on <a href="https://www.earthline.co.th">Earthline Company Limited</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h3>Molecular Breast Imaging</h3>
<p>The Dilon Molecular Imaging System is a specialized camera designed to image various organs. This system has been optimized to perform Molecular Breast Imaging (MBI) and is a strong diagnostic tool in early breast cancer detection. Using MBI as an adjunct to mammography results in an almost fourfold increase in invasive cancer detection in women with dense breast tissue. MBI has a higher specificity than MRI and has proven to reduce benign biopsies by 50%. With a negative predictive value of 98% MBI is the beacon in dense breast tissue. The system offers MBI biopsy capability which provides an additional tool to accurately localize the region of interest.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>The Dilon MBI procedure is an excellent problem-solving tool when faced with difficult-to-diagnose patients with:</p>
<p>• Dense Breasts<br />
• Inconclusive Mammograms<br />
• Lumps not seen by Mammogram<br />
• Family History of Breast Cancer<br />
• Breast Implants<br />
• Breast Cancer Survivor<br />
• Scar Tissue<br />
• Cannot have an MRI</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h3>WHAT CAN MBI DO?</h3>
<p><em>For the breast radiologist:</em><br />
• Find cancers missed by mammography and ultrasound, especially in difficult and dense breast cases, while leading to fewer benign biopsies than MRI<br />
• Provide a high negative predictive value to eliminate questionable findings on mammography and ultrasound</p>
<p><em>For the breast surgeon:</em><br />
• Improve surgical planning by finding additional disease<br />
• Provide a better understanding of the position of the tumor to help in surgical planning<br />
• Provide information useful in monitoring tumor response to chemotherapy</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h3>HOW DOES MBI WORK?</h3>
<p>MBI uses a pharmaceutical tracer that is absorbed by the breast tissue. The cancerous cells in the breast absorb a greater amount of the tracer than normal, healthy cells. As a result, the tracer “lights up” the cancerous areas inside the breast and the malignant cells appear as “dark spots” on the MBI image. Patients find the exam to be very comfortable, unlike mammography, as there is minimal compression and they are seated throughout the process.</p>
<p>Its similarity to mammographic positioning makes the MBI an easy modality for any trained mammographer to learn and use, and allows easy comparison to the original mammography views by the radiologist. The breast cancer scanning procedure may begin five minutes after the patient has been injected with a small amount of radioactive tracer (Tc-99m Sestamibi). The entire breast cancer screening study takes approximately 40-45 minutes and images are immediately available for a physician’s interpretation.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h3>MBI CLINICAL ASPECTS</h3>
<p>The Dilon Molecular Breast Imaging (MBI) Procedure can detect cancers missed by mammography and ultrasound, while leading to fewer benign biopsies than MRI. According to clinical studies, MBI has very high sensitivity for identifying earlier stage cancers as small as 1 mm. Clinical indications of MBI include:<br />
• Diagnosing breast cancer patients with an unresolved diagnostic dilemma<br />
• Equivocal exams<br />
• Dense-breast with indeterminate breast abnormalities<br />
• Breast implants<br />
• Discordant findings<br />
• As an alternate to MRI in patients who can not have an MRI study<br />
• Monitor for recurrence<br />
• Evaluate the extent of disease (initial staging)<br />
• Detect multi-centric, multi-focal, or bilateral disease<br />
• Assess response to neo-adjuvant chemotherapy<br />
• As an adjunct to a limited mammogram<br />
• Surgical planning for residual disease</p>

		</div>
	</div>

	<div class="wpb_video_widget wpb_content_element vc_clearfix   vc_video-aspect-ratio-169 vc_video-el-width-80 vc_video-align-center" >
		<div class="wpb_wrapper">
			
			<div class="wpb_video_wrapper"><iframe title="Dilon Diagnostics - BSGI with the Dilon 6800 Gamma Camera" width="500" height="281" src="https://www.youtube.com/embed/PJUtHoU-SBA?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe></div>
		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h3>Dilon 6800: Technical Specifications</h3>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">Digital Detector</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">Processing Mode</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Design</strong></p>
<p style="text-align: right;"><strong>Crystal Material</strong></p>
<p style="text-align: right;"><strong>Overall Size</strong></p>
<p>&nbsp;</p>
<p style="text-align: right;"><strong>FOV and UFOV</strong></p>
<p style="text-align: right;"><strong>Pixel Size</strong></p>
<p style="text-align: right;"><strong>Crystal Thickness</strong></p>
<p style="text-align: right;"><strong>Number of Crystals</strong></p>
<p style="text-align: right;"><strong>Photomultiplier Tubes</strong></p>
<p style="text-align: right;"><strong>Shielding</strong></p>
<p style="text-align: right;"><strong>Dead space</strong></p>
<p style="text-align: right;"><strong>Axes of Rotation</strong></p>
<p style="text-align: right;"><strong>Detector Rotation</strong></p>
<p style="text-align: right;"><strong>Detector Tilt</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>PSPMT &amp; Pixilated Crystals</p>
<p>NaI[Tl]</p>
<p>10.9 x 25.1 x 29.2 cm</p>
<p>[4.3 x 9.9 x 11.5 in]</p>
<p>15.2 x 20.3 cm [6.0 x 8.0 in]</p>
<p>2.96 mm x 2.96 mm</p>
<p>6 mm</p>
<p>3072</p>
<p>48</p>
<p>5 mm Pb</p>
<p>10 mm [0.4 in]</p>
<p>2</p>
<p>±130º</p>
<p>360º</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Databases</strong></p>
<p style="text-align: right;"><strong>Image Import/Export</strong></p>
<p style="text-align: right;"><strong>Processing Functions</strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p style="text-align: right;"><strong>Annotation</strong></p>
<p style="text-align: right;"><strong>Report Output</strong></p>
<p style="text-align: right;"><strong>Image File Output</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Local and remote</p>
<p>Interfile or DICOM</p>
<p>Threshold,</p>
<p>saturation, rotation,</p>
<p>smoothing, zoom</p>
<p>Text, box, arrows</p>
<p>BMP file, printer</p>
<p>BMP, JPEG, PNG</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">Imaging</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">System dimensions</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Intrinsic Spatial </strong></p>
<p style="text-align: right;"><strong>Resolution</strong></p>
<p style="text-align: right;"><strong>Energy Resolution</strong></p>
<p style="text-align: right;"><strong>Energy Range</strong></p>
<p style="text-align: right;"><strong>Uniformity</strong></p>
<p style="text-align: right;"><strong>Image Event Rate</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>3.3 mm</p>
<p>&nbsp;</p>
<p>13.5%</p>
<p>70 &#8211; 200 KeV</p>
<p>± 10% across full FOV</p>
<p>10k counts/sec (max)</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>System Total Weight</strong></p>
<p style="text-align: right;"><strong>SmartShield Weight</strong></p>
<p style="text-align: right;"><strong>System Dimensions</strong></p>
<p style="text-align: right;"><strong>(with retracted arm</strong></p>
<p style="text-align: right;"><strong>for storage and/or</strong></p>
<p style="text-align: right;"><strong>transportation)</strong></p>
<p style="text-align: right;"><strong>Arm Extension</strong></p>
<p style="text-align: right;"><strong>Maximum Arm Height</strong></p>
<p style="text-align: right;"><strong>Arm Vertical Travel</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>249 Kg [550 lbs]</p>
<p>5.5 kg [12 lbs]</p>
<p>132 (h) x 71 (w) x 127 (d)</p>
<p>cm [52 x 28 x 50 in]</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>86 cm [33.75 in]</p>
<p>103 cm [40.5 in]</p>
<p>51 cm [20.0 in]</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">Workstation</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">Operational Requirements</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Acquisition Workstation</strong></p>
<p>&nbsp;</p>
<p style="text-align: right;"><strong>Operating System</strong></p>
<p style="text-align: right;"><strong>Monitor</strong></p>
<p style="text-align: right;"><strong>Monitor Resolution</strong></p>
<p style="text-align: right;"><strong>Archival Medium</strong></p>
<p style="text-align: right;"><strong>Cables</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>PC, monitor, keyboard with</p>
<p>touchpad</p>
<p>Windows XP Pro</p>
<p>17 inch color flat panel</p>
<p>1280 x 1024 pixels</p>
<p>USB/CD-RW</p>
<p>Power and Ethernet</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Operating Temperature</strong></p>
<p style="text-align: right;"><strong>Storage Temperature</strong></p>
<p style="text-align: right;"><strong>Operating Humidity</strong></p>
<p style="text-align: right;"><strong>Storage Humidity</strong></p>
<p style="text-align: right;"><strong>Atmospheric Pressure</strong></p>
<p style="text-align: right;"><strong>Power or Voltage</strong></p>
<p style="text-align: right;"><strong>Frequency</strong></p>
<p style="text-align: right;"><strong>Current</strong></p>
<p style="text-align: right;"><strong>Power</strong></p>
<p style="text-align: right;"><strong>UPS Backup</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>18-30 ºC [65-85 ºF]</p>
<p>0-50 ºC [32-122 ºF]</p>
<p>30-80% (Non-condensing)</p>
<p>5-80% (Non-condensing)</p>
<p>70-105 kPa [10-15 lb/in2]</p>
<p>120 ~ 230 ~</p>
<p>60 Hz 50 Hz or 60 Hz</p>
<p>6 A 3 A</p>
<p>720 VA (max)</p>
<p>20 minutes (max</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">Acquisition</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">Communications</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Imaging Protocol</strong></p>
<p style="text-align: right;"><strong>Protocol Elements</strong></p>
<p>&nbsp;</p>
<p style="text-align: right;"><strong>Display Data</strong></p>
<p>&nbsp;</p>
<p style="text-align: right;"><strong>Persistence Screen</strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p style="text-align: right;"><strong>Peaking</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>User Definable</p>
<p>Organ, view, isotope, time/</p>
<p>counts, detector rotation</p>
<p>Elapsed time, acquired</p>
<p>counts, remaining time</p>
<p>Integral to workstation,</p>
<p>adjustable zoom and</p>
<p>refresh</p>
<p>Manual</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Hardware</strong></p>
<p style="text-align: right;"><strong>Protocol</strong></p>
<p style="text-align: right;"><strong>Data Format</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>10/100 Base T</p>
<p>Ethernet</p>
<p>DICOM 3.0 Interfile V3.3</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h4 style="text-align: right;">DICOM Services</h4>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p style="text-align: right;"><strong>Query/Retrieve, Print, </strong></p>
<p style="text-align: right;"><strong>Store</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Worklist Management</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div>
</div>The post <a href="https://www.earthline.co.th/product/dilon-6800/">Dilon 6800 Molecular Breast Imagine System</a> first appeared on <a href="https://www.earthline.co.th">Earthline Company Limited</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
